Mon-Fri 7:00am-5:00pm | Emergency 24 Hours
PACIFIC AIR Electrical & Air Conditioning
Electrical Safety & Storm Protection | AS/NZS 3000

Modern RCBO Switchboards & Whole-Home Surge Protection.

Replace outdated ceramic fuses, black asbestos panels, and crowded boards with individual 30mA Type-A safety switches and main-board surge protection before summer storms hit.

Modern residential switchboard upgraded with individual 30mA Type-A RCBO safety switches and main surge protection
Pacific Air & Electrical
QLD Contractors Lic. 94108 | ARC L198420
07 5550 4210
Modern white DIN-rail switchboard showing individual Type-A RCBO safety switches beside an orange surge protection module
Circuit-by-Circuit

Individual 30mA Type-A RCBOs

Helps limit disruption to the affected circuit when an appliance fault occurs.

Charcoal powder-coated Australian residential three-phase meter box mounted flush on a rendered exterior wall
Clean Enclosures

Meter Boxes & Asbestos Remediation

Safe licensed removal of old ceramic fuses and black asbestos backing panels.

Hardwired 32A home EV charger wallbox mounted cleanly inside a contemporary Gold Coast double garage
Ready For Modern Loads

40kA Storm Surge & EV Capacity

Shields expensive aircon inverter boards, TVs, and EV wallboxes from lightning spikes.

Modern RCBO & Surge Protection

Why upgrading an older Gold Coast switchboard protects both your family and your appliances.

Thousands of 1970s to early-2000s Gold Coast homes still rely on wire fuses or a single shared safety switch covering multiple power and lighting circuits. When a wet outdoor power point or ageing fridge leaks current, half the house blacks out at once. Worse still, a nearby summer lightning strike on overhead street lines can send voltage spikes straight into your ducted aircon boards, TVs, and smart appliances.

Lachlan strips out messy legacy wiring and rebuilds your enclosure cleanly with individual 30mA Type-A RCBOs (mandatory for modern inverter appliances and EVs) alongside a Type-2 40kA main surge diverter, earth electrode check, and printed circuit schedule.

Included & Available

Included in an Pacific Air & Electrical Switchboard Upgrade

  • Individual 30mA Type-A RCBO safety switch on every power & light circuit
  • Type-2 40kA whole-home lightning & grid-spike surge diverter
  • Main earth stake, MEN link, and Energex consumer mains inspection
  • Safe licensed remediation where old Zelemite/asbestos panels are present
  • Full AS/NZS 3000 testing & Queensland electrical compliance certificate
Interactive Switchboard Safety Guide

Toggle typical household circuits below or click 'Test 30mA Earth Fault Isolation' to see how individual RCBOs prevent whole-house blackouts:

Common Questions

Switchboard Upgrade Questions

Want Lachlan to check a quick photo of your current fuse box? Call Lachlan directly on 07 5550 4210.

What is the difference between a shared RCD and individual Type-A RCBOs?

A shared RCD groups 4 to 6 circuits onto one switch, so a single faulty toaster trips half the house and your fridge. Individual 30mA Type-A RCBOs give every single power, light, and AC circuit its own independent overload and shock breaker.

Why were Type-A safety switches made mandatory in Australia?

Modern inverter air conditioners, DC ceiling fans, induction cooktops, solar inverters, and EVs can produce pulsating DC earth faults that 'blind' older Type-AC switches. Type-A RCBOs detect both AC and pulsating DC leakage reliably.

Does a Type-2 40kA surge diverter protect my aircon and smart TVs?

Yes. Mounted inside your main switchboard, it diverts high-energy lightning and street-grid switching transients straight to earth before they reach appliance circuit boards.

Free Consultation & Written Quote

Upgrade your switchboard safely with Lachlan.

Obligation-free on-site consultations and clear written quotes from the Gold Coast to Brisbane South.

Request a Quote → Call 07 5550 4210
Call 07 5550 4210 24h Faults Quote
ShowcaseAll 7 BuildsLive Xero Portal